Sizing the 420094USP control module after installation on a GW11 or IWL12 model.
Last Updated: 01/26/2015
* The machine size must be set into the machine memory if a Motor Controller or Display Module has been changed.
To set the size:
1. Turn the power on at the power point and off at the console.
2. IWL12 -Press and hold the FABRIC CARE button, then press the POWER button. This will present a set of options in the LCD screen. The LCD screen has within it a number of options. Push the Adjust button to highlight the 650mm (L) machine size. Pushing the POWER button will lock the size into the module�s memory. GWL11 � Press and hold the WASH TEMP UP button then press the POWER button. Press the SPIN SPEED UP button (the HOLD LED should be on.)
3. Press the POWER button to return to normal operation.